To view a page, click its corresponding link. The management frame displays the page you selected. Check the Stopped error log and contact Quantum Customer Support if necessary. A library door is open. Door Open A tape drive is being cleaned. Page Status Chapter 3 Quantum Scalar 50 Remote Management Status Status page displays the general status or health of the library as well Status as specific hardware status.

The page also provides access to event logs as well as library statistics. To access the page, from the page, click on the Hardware Status Hardware tab at the top of the page. Page Figure 52 Statistics Page Chapter 3 Quantum Scalar 50 Remote Management Status Figure 52 Statistics Page Note: Statistics for individual elements a specific drive, slot, or port are included in the element detail window and can be viewed by clicking on a drive, slot, or port link from zoom windows accessed via the pages.

Page Find Page Chapter 3 Quantum Scalar 50 Remote Management Operations page allows the user to find and locate specific barcodes within Find Find Page the library as well as view the library contents slots, ports, drives, hand, or address.

To access the Page Quantum Scalar 50 User's Guide Chapter 3 Quantum Scalar 50 Remote Management Operations Find Barcode The find barcode section allows the user to find a specific barcode or partial barcode within the library and view its location. To toggle between physical and logical map, click the button in the map section. If the count field is left empty, only the starting cartridge is moved.

Page Inventory Page Chapter 3 Quantum Scalar 50 Remote Management Operations page allows the user to perform an inventory on all Inventory Inventory Page elements within the library or specific element ranges. The library must be off-line to perform an inventory. Note: To access the Page Setup Chapter 3 Quantum Scalar 50 Remote Management Setup To perform an action on a tape drive s 1 Select a cabinet and enter a tape drive number 2 Select the action to perform power off, power on, or reset.

Caution: Ensure that the tape drive does not contain a tape cartridge prior to powering down the tape drive. Page Identification Chapter 3 Quantum Scalar 50 Remote Management Setup The identification information is used to identify the library to assist Identification customer support when servicing the library.

The Users user access is also controlled from this section as well as email notification. The user name can be no more than seven characters. There is only one and the username is always Note: You can also determine the tape drive firmware revision from page. The TC web interface displays. Page Figure 65 Network Page 2 Edit the network information as desired see table 23 for a description of the fields.

Page Table 24 Email Notification Description Message Type: When a hardware failure occurs on the Quantum Critical Scalar 50 system such as a transition to a degraded, limited access, or failed system state, an email is sent to everyone on the critical failure recipient list. This allows the library to time stamp any events that occur.

Note: The Quantum Scalar 50 must be offline to adjust the time and date. Save The Quantum Scalar 50 will not use the new date and time zone information until it has been rebooted. Page Library Chapter 3 Quantum Scalar 50 Remote Management Setup The library configuration section allows the user to configure automatic Library library settings.

The library must be offline to change the library settings. Note: 1 To access the page, from the page, click on the Table 28 Capacity on Demand For example: in a Scalar 50 with two tape drives installed, only two partitions would be possible in this library. Page Figure 71 Partitions Page Chapter 3 Quantum Scalar 50 Remote Management Setup Figure 71 Partitions Page page contains a list of all user defined partitions and a Partitions section for either creating a partition or changing a partition's configuration and options.

Clicking on a partition name in the Select this box to return an Scalar 50 inquiry string Emulate Scalar to the host connected to this partition.

The partition will appear to the host as an P-Series tape library. If you are reducing the slot count, the slots are reduced from the highest element address first. Partitions Note: When a partition is added, edited, or deleted the library must be rebooted for the changes to take effect. Next page displays see figure Enter a name for the partition. Select a LUN for the partition. Exit Status Note: You must reboot the library for the changes to take effect.

Setup Wizard To assign a secure key to a cartridge: 1 Enter the barcode of the cartridge. Separate multiple barcodes with either spaces or commas. The must also contain at Any tape drives that have been secure key enabled will remain enabled, but the secure key will not be used to read or write cartridges. Page Quantum Scalar 50 User's Guide Tape Cartridge Migration Scenario In this tape cartridge migration example, tape cartridges have been secured in one tape library PX or Scalar 50 and you want to move them into another PX or Scalar 50 library and access them: 1 On the original library containing the cartridges: a Access the library remote management screens.

The action displayed on the button will depend on the current state of the library or cabinet. If the library cabinet is online, button will be displayed. The bridge rescan button re-discovers any iSCSI bridges installed in the cabinet. Details of the scan will be presented under s tab. Note: 1 Click the button.

Start Test The system performs a health test on all robotic axis. Previous test results can be viewed below. Note: 1 Select an action and a number of runs and click Apply The cabinet performs the system test.

If you leave the runs field empty, the system test will run continuously until you abort the system test. This configuration file should be saved on a local host on the same network.

If the library configuration file is corrupted, this backup configuration file can be uploaded back to the library without reconfiguring the entire library. Upload Drive Image The upload drive image section allows the user to remotely upload new tape drive firmware to a specific tape drive within the library. The log sense information for the tape drive displays. Click to see additional log sense information. This file can only used by Quantum Customer Support. Have this file available prior to calling Quantum Customer Support.

Note: It is recommended to turn the library offline prior to collecting an FA log. Clicking the link displays the following page Name Move Operation see figure Figure 96 Task List Example To logout of the library remote management pages, click Logout The session is closed. Start a new session by re-authenticating when prompted or close your browser.

Page Quantum Scalar 50 User's Guide Update the library firmware with the latest version of code. Start System A loader update was attempted. Hand-theta home fail The robotic hand could not home Critical Diagnostics the rotation axis. XY-motor fail zone The robotic hand has failed to Critical Diagnostics position the XY axis to a predetermined physical location.

Manager Could not change util The operating system has failed to Warning Drive timer modify a timer resource. Page Quantum Scalar 50 User's Guide The robotics did not detect a Warning Servo after get from magazine cartridge present when a tape was pulled from the magazine. Page Quantum Scalar 50 User's Guide The portion of the robotics that Warning Servo rotates can not move its respective motor to the expected internal limits.

Theta Axis Timeout The portion of the robotics that Warning Servo rotates theta could not position within its allotted time. Warning Sys manager unexpectedly cab index, state Unexpected response A firmware error has occurred. Shutdown timer expired Time limit has expired. Critical Sys monitor Unexpected error A firmware error has occurred. Critical Sys monitor returned from smgrEventDriveInserted index,status Unexpected error A firmware error has occurred.

Critical Sys monitor returned from smgrEventSensorChang e-adc 0,status Unexpected error A firmware error has occurred. Page Chapter 5 Troubleshooting Troubleshooting This chapter describes problems you may encounter during the setup and operation of the Quantum Scalar 50 library.

Corrective information is provided to help you resolve the problems. Several of these problems produce error messages on the OCP called Page Start-Up Problems If necessary, contact host system. If it still fails, contact a field service engineer. A flash memory Contact an authorized Quantum field service error is reported.

Page Power Supply Led Status The power supply is not attached to a power source or the power source has failed. DC OK off The power supply has failed. Green solid Drive failed No power to drive. Left yellow on Fibre Channel port active. Right yellow on Fibre Channel port active. Page Performance Specifications To that total length, add Swing the door open. The switch should snap back and forth, and the orange tab should be visible when the switch is in the write-protected position.

Position It is important to the library installation to locate the hole pattern in the rack rails see figure Threaded holes require neither cage or clip nuts to accept mounting hardware.

The rails within the rack have a hole pattern that repeats Note: throughout the rail. Page Appendix C Installing the Scalar 50 Library Installing the Library Figure Description Right and left support shelves left shown 4 sets Front and back rail mounting hardware M5 x 12 allen screws and mounting plates 2 sets Back bracket hardware M5 x 8 allen screws and Note: T-Nuts must be oriented so they fit in the grooves of the shelves.

At least two people are required to lift and install either library. Page Figure Back Mounting Brackets 2 Install the library into the rack as shown see figure Warning: The Scalar 50 weighs approximately 65 lbs 29 kg without power supplies or tape drives. The mounting clamps are Page Figure Turning On The Library 5 After the library has powered down, remove the hand restraint by completing the following steps see the Scalar 50 Quick Start Guide for more information : Remove the two thumb screws securing the hand restraint to the base of the library.

Caution: Avoid touching the printed circuit board. Caution: When removing the hand restraint, ensure that the robotics umbilical cable is lying down in the correct position inside the platform and not across the robotics track.

The Cabinet screen displays see figure : Figure Library Options Stack role Assigns the library stack role as Master, Slave, or Stand alone.

Note: Notes emphasize important in formation related to the main. Caution: Cautions indicate potential haz ards to equipment and are. Wa r n i n g : Warnings indicate potential ha zards to personal safety and. Note: It is recommended to review the entire document prior to. Content s 0.

Choosing a Location Rack Space Requirements Environmental Conditions Preparing for the Installation Providing Necessary T ools T aking ESD Precautions Unpacking the Scalar 50 T ape Librar y Installing the Library Locating the Mounting Position Initial Configuration